1. Instrument Overview This instrument is designed and manufactured in accordance with the requirements of T0625 "Asphalt Brookfield Rotational Viscosity Test (Brockfield Viscometer Method)" in the People's Republic of China industry standard JTJ052 "Highway Engineering Asphalt and Asphalt Mixture Test Regulations" It is suitable for measuring the absolute viscosity of Newtonian liquids and the apparent viscosity of non-Newtonian liquids. It can be widely used to measure the viscosity of various fluids such as asphalt, hot melt adhesives, paraffin wax, and polymers. 2. Main technical features 1. This instrument adopts advanced mechanical design technology, manufacturing technology and microcomputer control technology, with accurate data collection, high measurement sensitivity, reliable test results, convenient operation and beautiful appearance. 2. The display uses a white backlit, high-brightness LCD display, which can directly display the viscosity, rotor number, speed and other information of the sample, and the data is displayed clearly. 3. The test results can be displayed in real time on the display screen or printed out via a printer. In addition, through the RS232 data communication port of this instrument, it can also be connected to a personal computer. 4. With viscosity-temperature curve software, the curve can be used for data analysis and guide scientific research and production. 3. Main technical indicators and parameters 1. Measuring range: 25mPa·s~1×107mPa·s (the measuring range can be expanded to 2×107mPa·s with the option of No. 30 rotor); 2. Rotor specifications: 21, 27, 28, Four types of rotors of No. 29 (No. 30 rotors are optional); 3. Rotor speed: 0.1--200r/min stepless speed regulation, (built-in 12 speeds); 4. Measurement error: ±2% (F·S ), (±3%(F·S) when No. 30 rotor is selected); 5. Temperature control range: 25℃~200℃; 6. Temperature control accuracy: ±0.1℃; 7. Sample container volume: 20ml; 8. Working power supply: AC 220V±10%, 50Hz; 9. Ambient temperature: 5℃~35℃ (When the heater control temperature is close to room temperature, the air conditioner should be activated to make the working environment temperature lower than the heater control temperature by about 5℃ ); 10. The relative humidity of the environment: not more than 80%. 4. Optional accessories 1. NDJ-1F viscosity-temperature curve software 2. 30# rotor 3. Standard viscosity oil 4. One-time economical sample container

Product Description

1. Instrument Overview This instrument is designed and manufactured in accordance with the requirements of T0625 "Asphalt Brookfield Rotational Viscosity Test (Brockfield Viscometer Method)" in the People's Republic of China industry standard JTJ052 "Highway Engineering Asphalt and Asphalt Mixture Test Regulations" It is suitable for measuring the absolute viscosity of Newtonian liquids and the apparent viscosity of non-Newtonian liquids. It can be widely used to measure the viscosity of various fluids such as asphalt, hot melt adhesives, paraffin wax, and polymers. 2. Main technical features 1. This instrument adopts advanced mechanical design technology, manufacturing technology and microcomputer control technology, with accurate data collection, high measurement sensitivity, reliable test results, convenient operation and beautiful appearance. 2. The display uses a white backlit, high-brightness LCD display, which can directly display the viscosity, rotor number, speed and other information of the sample, and the data is displayed clearly. 3. The test results can be displayed in real time on the display screen or printed out via a printer. In addition, through the RS232 data communication port of this instrument, it can also be connected to a personal computer. 4. With viscosity-temperature curve software, the curve can be used for data analysis and guide scientific research and production. 3. Main technical indicators and parameters 1. Measuring range: 25mPa·s~1×107mPa·s (the measuring range can be expanded to 2×107mPa·s with the option of No. 30 rotor); 2. Rotor specifications: 21, 27, 28, Four types of rotors of No. 29 (No. 30 rotors are optional); 3. Rotor speed: 0.1--200r/min stepless speed regulation, (built-in 12 speeds); 4. Measurement error: ±2% (F·S ), (±3%(F·S) when No. 30 rotor is selected); 5. Temperature control range: 25℃~200℃; 6. Temperature control accuracy: ±0.1℃; 7. Sample container volume: 20ml; 8. Working power supply: AC 220V±10%, 50Hz; 9. Ambient temperature: 5℃~35℃ (When the heater control temperature is close to room temperature, the air conditioner should be activated to make the working environment temperature lower than the heater control temperature by about 5℃ ); 10. The relative humidity of the environment: not more than 80%. 4. Optional accessories 1. NDJ-1F viscosity-temperature curve software 2. 30# rotor 3. Standard viscosity oil 4. One-time economical sample container

Key words:Printing Equipment

Related Products

Welcome your message consultation